Skip to main content

Table 3 Accuracy, precision, recall, F1 score, and AP value for each algorithm

From: Can some algorithms of machine learning identify osteoporosis patients after training and testing some clinical information about patients?

Algorithms

Accuracy

Precision

Recall

F1 Value

AP Value

SVM

0.76

0.76

0.82

0.79

0.72

SGD

0.68

0.65

0.93

0.76

0.64

KNN

0.74

0.74

0.80

0.77

0.70

DT

0.72

0.78

0.69

0.73

0.71

RF

0.78

0.80

0.80

0.80

0.75

ET

0.76

0.79

0.78

0.78

0.74

XGB

0.76

0.78

0.79

0.79

0.73

LGBM

0.78

0.79

0.82

0.80

0.75

LR

0.75

0.78

0.86

0.77

0.72

  1. Note: AP Value, Average Precision Value